The test rig is used to test windows and doors for hurricane resistance. Standards: EN, ASTM E1886-05 and TAS. 
The test rig consists of two separate launchers for light 
and heavy projectiles mounted on a scissor lift, as well as control and measurement systems.

The test rig can be used as a stand-alone unit or, when connected to a computer via an RS485/USB link, as a remote-controlled system.

Both launchers operate by propelling the projectile using compressed air stored in a buffer tank. The muzzle velocity of the projectiles depends non-linearly on the pressure to which the tank is charged. A single mounted tank serves both launchers. 
When folded, the compact version fits into a transport space measuring 100x180x80cm.

03 April 2026

Pneumatic cannon for testing resistance to impact from light and heavy projectiles - mobile version

Basic position data:

                                              

General parameters

 

Position weight

approx. 130kg

Dimensions (length x width) with barrel removed

178 x 97cm

Minimum height of the large barrel from the ground:

66cm

Maximum height of the large barrel from the ground:

250cm

Minimum height of the small barrel from the ground:

51cm

Maximum height of the small barrel from the ground:

235cm

Electrical installation

 

Rated voltage

230 VAC

Power supply

single-phase

Length of power cable

approx. 4.5m

Power of the position

200W

External operating temperature:

0¸40°C

Humidity:

up to 50%

Pneumatic installation

 

Required pressure:

5÷8bar

Demand:

300 liters/min

Pressure connection:

quick connector

Measurements:

 

Pressure measurement range:

0÷10bar

Pressure measurement resolution:

0.01bar

Frequency of the electronic time-of-flight measurement system (both projectiles)

16MHz

Response time of the electronic time-of-flight measurement system (both projectiles)

1μs

Measurement range of small projectile speed:

0÷90m/s

Measurement base of the measuring system for small projectile:

100mm

Measurement range of large projectile speed:

0÷45m/s

Measurement base of the measuring system for large projectile:

100mm

Accuracy of projectile time-of-flight measurement:

0.05%