The test rig is used to test hydraulic fittings and determine the Kv and ξ coefficients in accordance with the PN-EN 1267 standard, as well as to test flow capacity and strength in accordance with the PN-EN 75002 standard. In addition, the test rig enables the determination of the opening pressure of a check valve and the measurement of the valve opening characteristic Q(α);
The test rig covers a wide range of diameters from DN15 to DN100. It allows for the testing of both straight and angle valves.
The test rig can operate autonomously or in conjunction with dedicated software, which significantly enhances its testing capabilities.
The control software enables:
- real-time calculation of characteristic values;
- adjustment (from the connected computer) of test parameters;
- real-time plotting of relevant graphs;
- easy archiving of measurement data and its export to an ASCII file or Excel.
Basic parameters of the station:
Range of tested diameters: DN15, DN20, DN25, DN32, DN40, DN50, DN65, DN80, DN100
Maximum pressure in the water installation: 10bar
Maximum pressure in the HP installation: 228bar
Water temperature during tests: 10-30°C
Dimensions (width x length x height): 428 x 382 x 260cm
Weight of the unfilled station: approx. 450kg
Weight of the filled station: approx. 1450kg
External operating temperature: 10¸40°C
Humidity: up to 50%
Measurements:
Number of electromagnetic flowmeters: 3
Measurement range of the DN25 flowmeter: 0.176-26.5m3/h
Measurement range of the DN50 flowmeter: 3.534-35m3/h
Measurement range of the DN100 flowmeter: 14-140m3/h
Flow measurement accuracy: 2%
Number of pressure transducers: 3
Range of the TL-MPM-1MF transducer: ±2bar (differential)
Accuracy of the TL-MPM-1MF transducer: 0.25%
Range of the ZX5046 transducer: 0-5bar (absolute)
Accuracy of the ZX5046 transducer: 0.5%
Range of the QDW-90A-JL transducer: 0-30bar (absolute)
Accuracy of the QDW-90A-JL transducer: 0.5%
Number of temperature sensors: 2
Type of temperature sensors: PT100
Temperature measurement range: 0-50˚C
Temperature measurement accuracy: 0.5 ˚C
Angle measurement range: 0-360˚
Angle measurement resolution: 0.18 ˚
Electrical installation:
Operating voltage: 3x400VAC
Power supply: three-phase
Length of power cable: 5m
Power: 16kW