The station is used to test the pressure resistance and tightness of the valve body assembly.
Functionally, the station consists of a high-pressure water pump and pressure stabilisation systems in a feedback loop.
The entire process is automated and performed under the supervision of a computer programme, which records the test and generates a test card.
Each element of the station, i.e. the mechanical part, the high-pressure installation, the electrical system and the software, was developed by Elbit.
Basic data of the workstation:
Basic parameters
External operating temperature: 10-40°C
Humidity: up to 50%
Operating voltage: 230 VAC
Power supply: single-phase
Length of power cable: 5m
Total power: 2.5kW
Type of operation: periodic 2min/h
Dimensions of the workstation (width x depth x height): 110 x 60 x 186cm
Capacity of the buffer tank: approx. 30dm3
Pressure sensor:
Measurement range: 60bar
Permissible overload: 120bar
Accuracy: 0.5%
Temperature sensor:
Type of sensor: resistive PT100
Measurement range: 0¸200°C
Measurement accuracy: 0.2%